Maintenance and cleaning
Before performing cleaning, adjusting, repairing
and maintenance tasks, the power cord must be
unplugged from the socket.
Replace worn out or damaged parts immediately, so
that the air compressor is always in a safe operating
condition.
Cleaning:
The compressor must be thoroughly cleaned after each
use.
Do not use aggressive cleaning products. These
products
may
damage
compromising the safe operation of the air compressor.
Maintenance:
Only maintenance works described in this instruction
manual may be carried out; all other works must be
performed by an official dealer.
Keep all nuts and screws firmly tightened.
If you remove components or safety devices to carry out
maintenance work, they must be replaced and
repositioned immediately and correctly.
Use only VITO-approved attachable accessories for this
appliance or technically identical parts. Failure to do so
may result in personal injuries or damages to the air
compressor. If in doubt, if you lack knowledge or
resources, you should contact an official dealer.
Technical assistance
The air compressor should only be serviced by the
brand's technical assistance center, or other qualified
personnel, replacing any necessary parts with original
parts.
38
plastics
and
metals,
ASSEMBLY INSTRUCTIONS
The compressor must be assembled with the wheels
and placed on a horizontal and firm surface, which is
capable of bearing its weight and vibrations during
operation. Never use the compressor in a surface with
a slope of more than 15°.
If the compressor is installed in a permanently fixed
structure, it is recommended to place dampers between
the air tank support base and the ground. The air tank's
support base must not be fixed directly on the ground.
The compressor must be installed in a well-ventilated
area and with enough space for maintenance tasks.
Ensure that the distances between the compressor and
any obstacle are enough to carry out these tasks. The
compressor must be at least 50cm away from any wall
or obstacle.
Avoid discharge pipes and extension cords that are too
long. If possible, the compressor should be installed
nearby the equipment's that will consume the
compressed air generated.
Install the compressor in a clean, dry and well-
ventilated location. Never install it in damp places or in
a location where there is a risk of being hit by water
projection.
Install the compressor in a room, free of dust,
chemicals, vapors, explosives or flammable gases.
Wheels and rubber feet
Rubber feet
1. Insert the rubber feet fixing screw into the holes in
the front supports (10) of the air receiver tank (2);
2. Place the washers and lock nuts on the screws;
3. Tighten the lock nuts;
Wheels
1. Line up the wheel (1) and rear support base holes.
Place the screw and tighten the nut;