Pressure setting on outlet valves with quick-release
coupling
The outlet pressure in the outlet valves with quick-
release coupling can be adjusted in the outlet pressure
regulator.
1. To adjust the outlet pressure, turn the pressure
regulator
(5)
clockwise
counterclockwise to decrease the pressure;
After each use, loosen the tank drain plug to drain the
pressure regulator.
MAINTENANCE AND CLEANING INSTRUCTIONS
Before carrying out any maintenance or cleaning work,
unplug the power cord from the socket, empty air
receiver tank and allow the compressor to cool down, in
order to avoid any accidental starts and burns.
Draining the condensed water off the air tank
To ensure a long service life of the air receiver tank, it is
advisable to drain the condensed water after each use
of the compressor, especially when it is used in moist
climates.
1. Unscrew the tank drain plug (11);
2. Wait until all the accumulated condensed water has
flowed out;
3. Tighten the tank drain plug;
The condensed liquid inside the compressed air
tank contains oil waste. Dispose of condensed
liquid in an environmentally friendly way at a proper
collection point.
to
increase
and
Oil changing
The oil function is intended to lubricate the parts in
constant friction, thus avoiding parts overheating and
wear.
To check the oil level, place the compressor on a flat,
horizontal surface. The oil level must be above the red
mark, which represents the maximum level on the oil
level sight glass (19).
If it is necessary to readjust the oil level:
1. Switch off the compressor and unplug the power
cord;
2. Unscrew and remove the oil filler/breather cap (18);
3. Add oil (15W40) to the appropriate level;
To change the oil, you must:
4. Place a suitable drain pan under the oil drain screw
(20);
5. Remove the oil drain screw and empty all the oil;
6. Once all the oil has been drained, place and tighten
the oil drain screw;
7. Use a funnel and fill with new oil;
8. Check the oil level and adjust it until the proper level
is reached;
9. Fit and tighten the oil filler/breather cap;
41