Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe
charge. Please check the "Where to Buy" section on
you.
European Correspondence Address*
Amprobe
Test Tools Europe
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
*(Correspondence only – no repair or replacement available from this address. European customers
please contact your distributor).
Specifications
General Specifications
Display and Update Rate: 3-5/6 digits 6000 counts; Updates 5 per second
nominal
Operating Temperature: 0 °C - 40 °C
Operating Relative Humidity: Maximum 80% R.H. up to 31 °C, decreasing linearly to
50% R.H. at 40 °C
Altitude: Operation below 2000 m
Storage Temperature: -20 °C ~ 60 °C, < 80% R.H. (with battery removed)
Temperature Coefficient: Nominal 0.15 x (specified accuracy)/ °C @
(0 °C ~ 18 °C or 28 °C ~ 40 °C), or otherwise specified
Sensing: Average sensing
Overload Protection: 450 V dc and V ac rms
Low Battery: Below approx. 2.4 V
Power Supply: 3 V standard button battery x 1 (IEC-CR2032; ANSI-NEDA-5004LC)
Power Consumption (typical): 2 mA
APO Consumption (typical): 2.2 µA
APO Timing: Idle for 3 minutes
Dimension / Weight
L 113 mm x W 53 mm x H 10.2 mm / Approx. 78 gm
Special Features
AutoTect (Automatic V and Ω selection) and VolTect (Electric Field Detection)
Test Tools distributor for a nominal
www.amprobe.com
10
for a list of distributors near