Introduction
Thank you for selecting the TidalWave TUP2000 Pool Cleanout Pump. Before using this
pump please take a moment to review this manual. This pump is designed to fit in most
pool main drains, to empty water down to 1/2" and to withstand the rigorous, corrosive
environments of pool and spa applications.
To avoid an accident do not use the pump in any way other than as described in this
manual. Please note the manufacturer cannot be responsible for accidents arising because
the product was not used as prescribed. After reading this manual keep it as a reference in
case questions arise during use.
MODEL
MAX FLOW
GPM
GPH
2040
TUP2000
LPM
LPH
Prior to Operation and Installation
When the pump is delivered, first perform the following checks:
• Check for any damage to pump and power cable that may have occurred during
the shipment.
• Check the model number to make sure it is the product that was ordered and verify the
voltage and frequency are correct.
Caution
• DO NOT operate this product under any condition other than those for which it is
specified. Failure to observe this precaution can lead to electrical shock, electrical
leakage, fire, water leakage or other problems.
• The pump is a 110/120 volt 60 Hz pump, please only use with a power supply voltage
within 110-120 volt 60 Hz.
• Never place your hand or any object in or near the inlet opening while this equipment
is operating. If pump inlet is clogged, always turn off the power supply, fuse box or circuit
breaker and wait until the motor is completely stopped before attempting to remove any
clogged material.
• Please make sure that the power plug and the AC outlet receptacle is protected and away
from water or pump discharge hose to prevent accidental electric shock or short circuit.
• Always operate the pump completely submerged in water.
• Avoid dry operation, which will not only lower performance but can cause the pump to
overheat/malfunction, leading to electrical leakage, shock or premature failure.
CAUTION:
•
THIS PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND CIRCUIT INTERRUPTER.
CAUTION:
•
THIS PUMP HAS BEEN EVALUATED FOR USE IN WATER ONLY.
WARNING:
•
RISK OF ELECTRIC SHOCK - THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND
GROUNDING-TYPE ATTACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC SHOCK, BE CERTAIN
THAT IT IS CONNECTED ONLY TO A PROPERLY GROUNDED, GROUNDING TYPE RECEPTACLE.
Before You Start
• Check the model name plate to make sure once again that the product is of the correct
voltage and frequency rating.
2
34
128
7722
5'
10'
29.5
23.8
1770
1428
111
90
6700
5405
15'
20'
17
4
1020
240
64
15
3861
908
25'