Descargar Imprimir esta página

Honeywell Home HM700ACYL2 Instrucciones De Instalación página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

HM700ACYL2
CAUTION
Equipment Damage
Failure to replace the cylinder at the end of
cylinder life will result in improper operation
and may result in damage to the humidifier.
Resideo is not responsible for any damages
resulting from, or attributed to, the failure to
replace a spent cylinder.
HIGH WATER SENSOR PIN HAS
A PLASTIC COLLAR AROUND IT.
CONNECT ORANGE HIGH WATER
SENSOR WIRE HERE.
ELECTRODE INTERNAL
MOUNTING POINT.
Removing the Cylinder
WARNING
Disconnect main power at the external
disconnect before any servicing.
The inside of the humidifier cabinet contains
high voltage components and wiring. Access
should be limited to authorized personnel.
1. Drain the existing cylinder by switching the On/
Off/Drain switch to the Drain position. Let the
humidifier drain until no more water is flowing
out to drain (usually not more than 10 minutes).
2. Turn the humidifier On/Off/Drain switch to off.
3. Close supply water shut off valve.
33-00159EFS—03
NOTE: Resideo recommends keeping a replacement
STEAM OUTLET
SECURE STEAM HOSE TO
OUTLET WITH HOSE CLAMP.
Fig. 2. HM700 Cylinder
4. Turn off power to the humidifier with the external
disconnect.
5. Remove the two screws securing the front cover.
6. Remove the cylinder plugs from the cylinder pins
by pulling vertically.
7. Using a flat screwdriver loosen the hose clamp
where the hose is connected to the cylinder.
8. Tip the top of the cylinder forward to pivot it out
of the steam hose. When free of steam hose lift
the cylinder out.
NOTE: The HM700 has a re-usable tie strap to
2
cylinder in stock throughout the humidifica-
tion season. This will prevent possible down-
time when the humidifier reports cylinder end
of life.
ELECTRODE PIN
CONNECT COLOR CODED CYLINDER
PLUGS TO PIN WITH CORRESPONDING
COLOR LABEL. THE SPRING LOADED
PLUG SHOULD FIT SNUGLY ON THE PIN.
REPLACE IF LOOSE OR ANY SIGNS OF
DAMAGE.
LABEL
IDENTIFIES CYLINDER INFORMATION.
ALSO INCLUDES SAFETY INFORMATION
AND CONTACTS.
secure the cylinder for transit as well as
home installation. This must be
removed or loosened to remove the
cylinder.
M35704