HM700ACYL2
Installing the New Cylinder
CAUTION
Verify Model Number
Make sure the new cylinder is the same model
as the one that was removed. Model number is
on top left corner of cylinder label. Only
HM700 replacement cylinders can be used.
1. Insert cylinder into drain valve. Tilt cylinder
forward and fit end of steam hose to steam
outlet. Tip cylinder back into place.
2. Tighten hose clamp, being careful not to over-
tighten and crush the plastic cylinder steam
outlet.
3. Attach color-coded cylinder plugs to the
corresponding color-coded cylinder pin. Push
down completely. Connect high water sensor
Resideo Inc., 1985 Douglas Drive North,
Golden Valley, MN 55422
www.resideo.com
33-00159EFS—03 M.S. Rev. 07-19 | Printed in United States
This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502
©2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved.
ACTUATOR
SPRING
(NOTE ORIENTATION)
SLEEVE AND
SOLENOID
Fig. 5. Drain Valve Actuator Assembly
For more information on maintenance and
replacement, please visit http://honeywellhome.com
or call 1-800-468-1502 or 1-800-814-9452
PLUNGER
plug. Spring-loaded plugs should fit snugly
onto the cylinder pin. Replace if they are loose
or damaged.
4. Replace the humidifier cover and secure with
two screws.
5. Turn on power to humidifier with the external
disconnect.
6. Open supply water shut off valve.
7. Turn the humidifier On/Off /Drain switch to On.
NOTE: The HM700 has a re-usable tie strap to
secure the cylinder for transit as well as
home installation. This must be
removed or loosened to remove the cyl-
inder. Secure when new cylinder is
installed.