Descargar Imprimir esta página

Lamborghini Caloreclima EM 26-E Manual Para La Instalación Y El Mantenimiento página 33

Ocultar thumbs Ver también para EM 26-E:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

WIRING DIAGRAM - EM 26-E BURNER
The connections to be carried out by the installer are:
- Main supply line
- Thermostatic line
- Lock-out lamp at terminal S3 (if present)
- Hour counter at terminal B4 (if present)
Legend
EC
Control electrode
F
Fuse
FA
Anti-interference filter
IG
Main switch
Ima
ON/OFF switch
NOTE: Always make sure that no more than two wires are connected to each terminal.
Warning:
- Do not invert the neutral with the phase.
- Make the connection to an efficient earthing system.
- The electrical power line to the burner must be fitted with an omnipolar switch with an opening of at least 3 mm between
the contacts.
- The earth connection to the terminal board of the burner must be made with a cable at least 20 mm longer than the phase
and neutral cables.
- Must be workmanlike performed and comply with the regulations in force.
LI
Switch light
MB
Burner motor
MPE Control box terminal board
PA
Air pressure switch
PGm Minimum gas pressure switch
- 33
-
Mains supply
230V-50Hz
TC
Boiler thermostat
TR
Ignition transformer
TS
Safety thermostat
VP
Main safety valve
VS
2nd safety valve

Publicidad

loading

Este manual también es adecuado para:

Em 16-e