Descargar Imprimir esta página

Broan PM400SS Instrucciones De Instalación, Uso Y Cuidado página 16

Ocultar thumbs Ver también para PM400SS:

Publicidad

Idiomas disponibles

Idiomas disponibles

WIRING
Risk of electric shock . Electrical wiring must be
done by qualified personnel in accordance with all
applicable codes and standards . Before connecting
wires, switch power off at service panel and lock
service disconnecting means to prevent power from
being switched on accidentally .
1 . Using appropriate wire nuts (not included), connect house
power cable to unit wiring: BLACK to BLACK, WHITE to
WHITE and GREEN or bare wire to GREEN ground screw
(FIG . 30) .
2 . Reinstall the electrical cover in the unit; ensuring the bottom
tabs are inserted in their embossed location . Secure in
place using its retaining screw (FIG . 31) .
Take care not to pinch wires while reinstalling wiring
cover .
INSTALL THE FILTER(S)
Ducted Installation
Reinstall the grease filter(s) .
Non-Ducted Installation
PM400SS unit only: Attach the non-ducted filter (included
with the HARKPM21 non-duct kit) to the back of the
grease filter using clips (provided with non-ducted filter) .
To order a new non-ducted filter, use service part number
S99010464 .
BBN2243SS and BBN2303SS units only: Attach
the non-ducted filters (included with the HARKBN24
or HARKBN30 non-duct kit) to the back of the grease
filters using clips (provided with non-ducted filter) . To
order new non-ducted filters, use service part number
S99010464-124 for BBN2243SS and S99010464-130
for BBN2303SS model .
16
!
WARNING
CAUTION
WHITE WIRE
GREEN
GROUND
SCREW
HE0432
HD1379
BLACK WIRE
HOUSE
POWER
CABLE
FIG. 30
TABS
FIG. 31

Publicidad

loading

Este manual también es adecuado para:

Bbn2243ssBbn2303ss