(if supplied and packed with the
Magnetic ring
accessories)
1 2 3
Power Specifications
NOTE: Electric auxiliary heating type circuit breaker/fuse need to add more than 10 A.
MODEL(Btu/h)
PHASE
POWER
VOLT
CIRCUIT BREAKER/
FUSE(A)
MODEL(Btu/h)
PHASE
POWER
CIRCUIT BREAKER/FUSE(A)
Pass the belt through
the hole of the Magnetic
ring to fix it on the cable
Outdoor Power Supply Specifications
≤18K
19K~24K 25K~36K 37K~48K 49K~60K
1 Phase
208-240V 208-240V 208-240V 208-240V 208-240V
25/20
≤36K
3 Phase
380-420V
VOLT
25/20
CAUTION
While connecting the wires, please strictly follow
the wiring diagram.
The refrigerant circuit can become very hot.
Keep the interconnection cable away from the
copper tube.
4. Clamp down the cable with the cable clamp.The
cable must not be loose or pull on the u-lugs.
5. Reattach the electric box cover.
1 Phase
1 Phase
32/25
50/40
≤36K
37K~60K
3 Phase
3 Phase
380-420V
208-240V
32/25
32/25
1 Phase
1 Phase
70/55
70/60
37K~60K
3 Phase
208-240V
45/35
Page 35