Descargar Imprimir esta página

CORBERO CC510GB90X Manual Del Usuario página 41

Ocultar thumbs Ver también para CC510GB90X:

Publicidad

Idiomas disponibles

Idiomas disponibles

Using Cooker Section
Using Gas Burners
FFD
1. The valves controlling the gas cookers have special security mechanism.
In order to light the cooker always press on the switch forward and bring it to
flame symbol by turnin counterclockwise. All of the lighters shall operate and
the cooker you controlled shall light only. Keep the switch pressed until
ignition i performed. Press on the lighter button and turn the knob counter
clockwise.
2. Do not continuously operate the igniter for more than 15 seconds. If the
burner does not ignite, wait minimum one minute before try again.
3. In models with gas security system, when flame of the cooker is
extinguished, control valve cuts off the gas automatically. For operate the
burners with gas security system you must press the knob and turn counter-
clock-wise. After the ignition you must wait nearly 5-10 second for gas
security systems activation. If the burner is extinguished for of the any reason,
close the gas control valve and wait a minimum of one minute before trying
again.
4.
Closed
5. Before operating your hob please make sure that the burner caps are well
positioned. The right placement of the burner caps are shown as below.
Figure 18
Flame cut-off safety device (FFD) *; operates instantly
when safety mechanism activates due to overflown
liquid over upper hobs.
Fully open
41
Half open
Figure 19

Publicidad

loading

Este manual también es adecuado para:

Cc510gb90wCcsf5gb922wCcsf5gb922x