4
Commissioning
4.1 Preliminary checks
Before commissioning the dryer, make sure:
• installation was carried out according that given in the section
3;
• the air inlet valves are closed and that there is no air fl ow
through the dryer;
• the power supply is correct.
4.2 Starting
QS
a) Start the dryer before the air compressor by means of the main
power switch "QS", the display shows "DRY"
b) after at least 5 minutes slowly open the air inlet valve and
subsequently open the air outlet valve: the dryer is now perform-
ing its air drying function.
4.3 Operation
a) Leave the dryer on during the entire period the air compressor
is working;
b) the dryer operates in automatic mode, therefore fi eld settings
are not required;
c) in the event of unforeseen excess air fl ows, by-pass to avoid
overloading the dryer.
4.4 Stop
a) Stop the dryer 2 minutes after the air compressor stops or in
any case after interruption of the air fl ow;
b) do not allow compressed air to fl ow through the dryer when
the latter is not running;
c) switch off at the main power switch «QS». The power light
goes out and the compressor stops.
English
5
Control
QS
Main power switch
UP button: press to increase the value of a selected
parameter
DOWN button: press to reduce the value of a selected
parameter
esc
ESC button :returns to the previous level
SET button : one single press to see the alarms, press
set
for more seconds to enter Menu (Service e Factory)
;
(lit) Dew point correct
(Flashing) warning dew point high/low
(off) alarm dew point
(lit) Condensate drain ON
(off) Condensate drain OFF
(lit) Multiple alarms
(Flashing) Warning "maintenance"
Degree
SPS004-SPS100
5.1 Parameter settings
There are two levels of protection for parameters:
a) User (U): with immediate access, User-changeable;
b) Password protected Factory/Service (F/S): password required
for access; Factory-set parameters.
Condensate drain
There are two operating modes:
a) TIMED (TIm) - with draining at intervals and settable time;
in this confi guration keep pressed
work;
b) EXTERN (CON) - if there is an external drain.
For chosing the set proceed as follows::
set
Press button
over 5 seconds to enter on menu U.
Using buttons
and
select "CHd" and press
fi rm.
Using buttons
and
select "TIm" or "CON" .
esc
Press
to confi rm and exit.
In the same way it is possible to change interval and discharge
times of the drain.
to force the drain to
set
to con-
3 / 6