INTRODUCTION
Storage heaters are designed to take advantage of the considerable economical benefits of any restricted hour electricity
tariff.
The heaters consume electricity only during the off-peak tariff, but due to the highly efficient storage medium, give you a
truly economical 24 hours of comfort temperatures. Supply with 220-240V~.
Power
Type
(W)
AX 84
800
AX 124
1200
AX 168
1600
AX 208
2000
AX 2412
2400
ADS 3216
3200
AX 84 /14
450
AX 124 /14
675
AX 168 /14
900
AX 208 /14
1125
AX 2412 /14
1350
AX 3216 /14
1800
The CARGA control operates a highly sensitive thermostat which regulates the amount of heat stored.
The discharge is by convection heat which can be partially controlled by use of the DESCARGA control. Please note that
types AX 84 and AX 84/14 are fully automatic with no DESCARGA control.
It is important that the correct rating of heater is installed to provide the selected level of heat. This will ensure the best
possible running costs against other fuels.
To reduce transport problems, the heater casings and storage bricks are packed separately. You should be aware that
Storage heaters, when fully charged, can have high surface temperatures.
2. INSTALLATION INSTRUCTIONS
1.- Chose the right place to install the heater. It is necessary that a minimum clearance of 50 cm is allowed to ensure the
best heating results. Always maintain a minimum clearance of 50 cm from the heater to any combustible materials such as
furniture and curtains.
2.- Open the carton at the indicated side and fix the feet without removing the heater casing (fig 1). The screws are in the
accessories bag. Turn the carton upside down to allow the heater to stand on its feet and remove the carton. Check that it
is the correct model and that it is in good condition.
3.- Take off the front panel by removing the two screws at the bottom of the heater.
4.- Set the heater in the selected installation area and mark the fixing points on the wall using a pencil. Use the heater fixing
holes as a template and mark the wall through the fixing holes. Drill the required holes into the wall.
Charge
Total
(kWh)
Weight (kg)
6.4
39
9.6
56
12.8
73
16.0
90
19.2
108
25.6
142
6.3
39
9.4
56
12.6
73
15.7
90
18.9
108
25.2
142
fig 1
Brick
L x W x H
7,5 kg
31.5 x 15 x 72.5
43 x 15 x 72.5
54 x 15 x 72.5
65 x 15 x 72.5
76.5 x 15 x 72.5
99 x 15 x 72.5
31.5 x 15 x 72.5
43 x 15 x 72.5
54 x 15 x 72.5
65 x 15 x 72.5
76.5 x 15 x 72.5
99 x 15 x 72.5
fig 2
7
Bricks
Charging
11,5 kg
time
4
-
8 h
-
4
8 h
8
-
8 h
4
4
8 h
12
-
8 h
16
8 h
4
-
14 h
-
4
14 h
8
-
14 h
4
4
14 h
12
-
14 h
16
14 h