Cost-Saving Efficiency
The Little Giant Professional Series of pumps produce a maximum flow rate with minimal electrical consumption.
The dollars saved from reduced operating costs can pay for the pump in a matter of months.
Safety
The Professional Series are end suction centrifugal pumps, designed to be located on the perimeter of the
pond. This eliminates the need for wading into the pond to service the pump or pump intake filter. By locating
the pump outside of the pond, you also greatly reduce the chance of electrical shock.
Reliability
The Professional Series was designed with the professional in mind. Built tough, the pump housings are injection-
molded of corrosion-resistant thermoplastics, and are mounted to custom-built motors. Each Professional
Series pump is thoroughly tested prior to shipment. When properly installed, your pump is designed to
provide years of dependable, reliable service.
Quiet Operation
Install these pumps wherever you desire. The Professional Series was designed for water gardening, not industrial
applications, generating noise levels equivalent to a small electrical fan at 52 dB.
NOTE: For above the water level applications, a leaf basket (566106), is required to act as a priming chamber.
OPWG-71/97
Features
Thermally protected, enclosed, fan cooled,
permanent split capacitor motor
115V or 230V operation (pre-wired for 115V)
1-1/2" FNPT intake and discharge ports
Motors are enclosed for excellent protection
and weather resistance
Low power consumption
For larger systems, plumb two or more units in
parallel to economically multiply the flow
Construction
Volute — Corrosion-resistant thermoplastic
Volute Cover — Corrosion-resistant thermoplastic
Impeller — Glass-filled Noryl
Shaft Seal — Carbon/Ceramic
Out-of-Pond
WG Pumps
®

Publicidad

loading

Resumen de contenidos para Little Giant OPWG-71

  • Página 1 Shaft Seal — Carbon/Ceramic Cost-Saving Efficiency The Little Giant Professional Series of pumps produce a maximum flow rate with minimal electrical consumption. The dollars saved from reduced operating costs can pay for the pump in a matter of months. Safety The Professional Series are end suction centrifugal pumps, designed to be located on the perimeter of the pond.
  • Página 2 Height Length Width Listings Size Size Volts Hertz Amps Watts Feet (lbs.) (in.) (in,) (in.) OPWG-71 566023 UL/CSA 1-1/2" FNPT 1-1/2" FNPT 1/8 115/230 2.5/1.3 24.86 8.75 15.50 9.00 OPWG-97 566024 UL/CSA 1-1/2" FNPT 1-1/2" FNPT 1/4 115/230 3.5/1.7 24.90 8.75...
  • Página 3 Hardware ..................Stainless steel LEAF BASKET (OPTIONAL) Little Giant offers an optional leaf basket for use with the OPWG pumps. The leaf basket is important for providing filtration to the water in the pond and keeping large debris from going into the pump. The leaf basket is a necessity for installations where the pump is located above the water source (Figure 3).
  • Página 4 2” NPT 1-1/2” NPT 8’ Skimmer, pond, or filter 566021 OPWG-46 2” NPT 1-1/2” NPT 8’ Pump 566023 OPWG-71 1-1/2” NPT 1-1/2” NPT 115/230 Standard 2” gate valve NOTE: Close this valve ONLY 566024 OPWG-97 1-1/2” NPT 1-1/2” NPT 115/230 when servicing pump or cleaning leaf basket.
  • Página 5 PANIER À FEUILLES (EN OPTION) (no service required). The shaft seal requires no lubrication after assembly. Little Giant offre en option un panier à feuilles utilisable avec les pompes OPWG. FREEZING TEMPERATURES: Drain the pump of water before servicing or if Le panier à...
  • Página 6 LA BOMBA FUERA DE ESTANQUE PARA JARDÍN ACUÁTICO. La bomba fuera El producto Little Giant que ha adquirido se fabrica utilizando mano de obra y de estanque para jardín acuático no es autocebante; por lo tanto, si la fuente materiales de la más alta calidad y ha sido diseñado para prestarle un servicio...
  • Página 7 1. Determine la ubicación adecuada para montar la bomba en forma 5. Retire los cuatro 4 pernos que sujetan la abrazadera al motor. No permanente en un lugar cercano a la fuente de agua (succionador, filtro, introduzca la punta del destornillador en el motor para palanquear las hojas etc.) Existen tres (3) opciones de instalación de la bomba fuera de estanque del ventilador, ya que esto dañará...
  • Página 8 TROUBLESHOOTING PROBLEM • PROBLÈME • PROBABLE CAUSES • CAUSES PROBABLES • CAUSAS CORRECTIVE ACTION • MESURE CORRECTIVE• ACCIÓN CORRECTIVA PROBLEMA PROBABLES Motor will not rotate. • Le Blown fuse or breaker. •Le fusible est grillé ou le disjoncteur Check main power box for blown fuse or tripped circuit breaker, etc. • Vérifier le panneau principal de moteur ne tourne pas.
  • Página 9 Any product that should fail for either of the above two reasons and is still within the warranty 2. Product connected to voltage other than indicated on nameplate. period will be repaired or replaced at the option of Little Giant as the sole remedy of buyer. 3. Cord cut off to a length less than three feet.
  • Página 10 CONTINENTALES: Por favor, devolver la unidad defectuosa, con el porte pagado, a la La présente garantit que votre pompe Little Giant est en parfaite condition à sa sortie de fábrica en P. O. Box 12010, Oklahoma City, OK 73127-6616. Todo producto defectuoso l’usine.

Este manual también es adecuado para:

Opwg-97