Descargar Imprimir esta página

Grundig GDKP5460BC Manual Del Usuario página 14

Ocultar thumbs Ver también para GDKP5460BC:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33
INSTALLATION OF APPLIANCE _______________________
Installation of Air Baffle
While using with the carbon filter, air baffle is
provided with your appliance with the aim of
re-releasing the air which is cleaned with car-
bon filter from the perforated located on the
Chimney . Assemble the air baffle as below.
(Fig. 13)
There is a tab in the middle of the Chimney
connection plate. Place the middle point of
this tab on the line that is drawn perpendic-
ular to the wall. Align horizontally and mark
the holes where the connection plate will be
mounted via a pen (Figure 13 / A, B).
Drill the marked points with Ø6mm drill and
insert two Ø6mm plastic dowels in the drilled
holes (Figure 13 / A, B).
Fix the Chimney connection plate to the wall
with 3.9x22 screws (Figure 13/ A, B).
For air baffle assembly, install point C, D, E,
F with Ø6mm drill and Ø6mm plastic dowels
(Figure 13).
(Fig. 14)
1- Air Baffle
2- Plastic Chimney
14 ENGLISH
1
2
Attach the plastic Chimney adapter, which is
included in the package, in the direction of the
air baffle. Lock the Chimney adapter by turn-
ing it in the direction of the arrow (Figure 14).
(Figure 15)
Assemble the air baffle group with 3.9 x 22
screws from point C, D, E, F that you have
already prepared (Figure 13).
Assemble the hood body (Page 12 / Figure 7).

Publicidad

loading