Translation of the original instructions
• Lithium charging curve :
The GYSflash 30.12 PL uses a 8 steps charging curve which guarantees optimal performance for your LFP battery.
U
I
Analysis
< 1s
CHARGE
OK
1
Step
: Analysis
Analyses the battery state (charge level, polarity inversion, wrong battery...)
2
Step
: Recovery (
Recovering damaged elements due to a prolonged deep discharge.
3
Step
: Charge (
Maximum current fast charge to reach 90% charge level.
4
Step
: Absorption (13.8 V)
Constant voltage charge to reach 98% charge level.
• Estimated charge time :
Charging current
Battery capacity
Charge timing
0% >>> 90%
• Protections :
The GYSFLASH 30.12 PL has comprehensive safety features to protect it against short-circuits and polarity reversals.
It has an anti-spark feature which prevents sparks whilst connecting the device to the battery. This charger has
double insulation and is safe to use with the battery in situ as it will protect the vehicle's on-board electronics.
The GYSFLASH 30.12 PL is fitted with an integrated temperature sensor that ensures that the charging current is adapted to the
ambient temperature to prevent internal the electronics from overheating.
12
GYSFLASH 30.12 PL
1
2
3
Recovery
Charge
Max 5 min
Max 25 h
- 0.5 A /
- 1 A /
- 7 A /
- 15 A /
Lead-acid
15 Ah 60 Ah 60 Ah 100 Ah 100 Ah 220 Ah
2 h
8 h
4 h
6 h
4
5
Equalizing Battery System
Absorption
Test
Supplement
Max 20 h
3 min
Max 10 h
Step
Charge conservation test.
Step
- 2 A)
Reduce current charge to reach 100% charge
level.
Step
- 30 A)
Balancing of battery cells.
Step
Maintains battery charge level at its maximum
and goes through charge maintenance cycle
every 10 days.
375 Ah
7 Ah 15 Ah 15 Ah 30 Ah 30 Ah 220 Ah 375 Ah
3 h
7 h
12 h
6
7
Equalizing /
balancing
Max 2 h
(maintenance cycle every
5
: Test
6
: Supplement
7
: Equalizing / balancing (14.4 V)
8
: Floating charge (13.8 V)
Lithium
1h
2h
1h
2h
EN
8
Floating charge
No limit
10 days.)
1h
7h
12h