Time zone: To display the time of your time-zone, change the time zone in CLOCK setting
mode from '00' (default) to your time zone (e.g.08 for Hong Kong).
1. Press and hold [ CLOCK SET ] key for 2s to enter time setting mode.
2. Press [
] or [
confirm and exit. Please refer to MANUAL CLOCK SETTING session of manual for details of
other setting for the console.
The time will automatically synchronize Internet time server at 12:00AM and 12:00PM per day.
Also you can press the [REFRESH ] key to get the internet time manually within 1 minute.

ADVANCE SETTING IN WEB INTERFACE

Press "ADVANCED" key at the top of web interface to enter the advance setting page, this
page allow you to set and view the calibration data of the console, also you can update the
firmware in here (Only available in PC platform).
Select setting unit
Temperature
calibration section
Pressure
calibration section
calibration section
calibration section
CALIBRATION
1. User may enter or change the offset and gain values for different measurement parameters
while current offset and gain values are shown next to their corresponding boxes.
2. Once completed, press
The current offset value will show the previous value that you entered, if you want to change,
just input the new value in the blank, the new value will valid once you press
SETUP page.
NOTE:
Calibration of most parameter is not required, with the exception of Relative Pressure, which
must be calibrated to sea-level to account for altitude effects.
] key to enter your time zone, then press and hold [ CLOCK SET ] key to
SETUP
Temperature
Indoor
Current offset: 1
Outdoor
Current offset: -9
CH 1
Current offset: 2
CH 2
Current offset: 3
CH 3
Current offset: 1.2
CH 4
Current offset: -0.2
CH 5
Current offset: -20.1
CH 6
Current offset: 11.5
CH 7
Current offset: 0.2
Range: -20.0 ~ 20.0
-36.0 ~ 36.0
o
F (Default: 0.0)
Absolute Pressure Offset:
Relative Pressure Offset:
Setting Range:
-560~ 560hpa / -16.54 ~ 16.54inHg / -420 ~ 420mmHg
Rain
**Rain gain:
Wind
**Wind speed gain:
**Wind direction:
**UV gain:
**Light gain:
** Depend on the model
Function firmware version: 1.00
WiFi firmware version: 1.00
in the SETUP page
Apply
Language:
English
ADVANCED
o
C
Humidity %
Current offset: -5
Current offset: 10
Current offset: -5
Current offset: -2
Current offset: -2
Current offset: -5
Current offset: -3
Current offset: -10
Current offset: -3
o
C
Range: -20 ~ 20
(Default: 0.0)
Pressure
hpa
Current offset: -3
(Default: 0)
Current offset: 10
(Default: 0)
Current gain: 0.85
Range: 0.5 ~ 1.5(Default: 1.00)
Current gain: 0.75
Range: 0.5 ~ 1.5(Default: 1.00)
Current offset: 2
o
o
Range: -10 ~ 10(Default: 0
)
Current gain: 1.1
Range: 0.01 ~ 10(Default: 1.00)
Current gain: 1.0
Range: 0.01 ~ 10(Default: 1.00)
Advancd page
14
Press "ADVANCED" icon
to advancd page
Humidity
calibration section