WARNING:
Before inspecting, cleaning or servicing the machine, shut
off motor, wait for all moving parts to stop, disconnect
unit from power supply, and pull trigger to release water
pressure. Failure to follow these instructions can result
in serious personal injury or property damage.
WARNING:
Always wear eye protection with side shields marked to
comply with ANSI Z87.1. Failure to do so could result in
objects being thrown into your eyes, resulting in possible
serious injury.
WARNING:
When servicing, use only identical replacement parts.
Use of any other parts could create a hazard or cause
product damage.
NOTICE:
Periodically inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts,
caps, etc. Tighten securely all fasteners and caps and
do not operate this product until all missing or damaged
parts are replaced. Please contact customer service or
a qualified service center for assistance.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline, petroleum-
based products, penetrating oils, etc., come in contact
with plastic parts. Chemicals can damage, weaken or
destroy plastic which could result in serious personal
injury.
POWER SUPPLY CORD REPLACEMENT
If replacement of the power supply cord is necessary, this
must be done by an authorized service center in order to
avoid a safety hazard.
MAINTENANCE
PUMP LUBRICATION
The pump on this unit is lubricated with a sufficient amount
of high grade lubricant for the life of the unit under normal
operating conditions. Therefore, no further lubrication is
required.
PUMP MAINTENANCE
Routinely make a visual inspection of the pump. If you notice
any leaking of lubricant around the pump seals, take the
pressure washer to an authorized service center for repair.
There are no user serviceable parts to the pressure washer
pump. Any attempt to service or alter the pump may dam-
age the pressure washer and void your product warranty.
NOZZLE MAINTENANCE
See Figure 20.
Excessive pump pressure (a pulsing sensation felt while
squeezing the trigger) may be the result of a clogged or
dirty nozzle.
 Unplug the pressure washer.
 Turn off the pressure washer and shut off the water
supply. Pull trigger to release water pressure.
 Remove the nozzle from the spray wand.
WARNING:
NEVER remove nozzles without first turning off the
motor, and locking the lock out on the trigger handle.
NEVER point the nozzle at your face or at others. The
quick-connect feature contains small springs that could
eject the nozzle with some force. Failure to follow these
instructions could result in an eye injury or other serious
personal injury.
 To free any foreign materials clogging or restricting the
nozzle, blow out or remove debris with a straightened
paper clip or fine needle.
 Using a garden hose, flush debris out of nozzle by back
flushing (running the water through the nozzle backwards
or from the outside to the inside).
 Reconnect the nozzle to the spray wand.