Descargar Imprimir esta página

Flotec FP415515H Manual Del Usuario página 7

Publicidad

Idiomas disponibles

Idiomas disponibles

New Shallow Well Convertible Pump Installation
Replace Pressure
Regulator with
Priming Tee
(see fig. 1)
Relief Valve
To Household
Sanitary
Water System
Well Seal
Well
Casing
At least
10'
Strainer
5-10'
5974 0309
Figure 7: Cased Well Installation
Replace Pressure
Regulator with
Priming Tee
(see fig. 1)
Relief Valve
To Household
Water System
Figure 8: Driven Point Installation
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
All manuals and user guides at all-guides.com
Shallow Well Installations
Step 1. Remove the control valve from the pump body. Replace it with a
Step 2. Install the ejector kit. Follow the instructions provided with the kit.
Suction Pipe
From Well
Priming
Tee and
Plug
Cased Well Installation, 2
(Figure 7)
Step 3. Mount the pump as close to the well as possible. Connect the pipe
Step 4. Assemble the foot valve, strainer, and well pipe (see Figure 7). Make
Step 5. Lower the pipe into the well until the strainer is five feet above
Driven Point Installation (Figure 8)
Step 3. Drive the well, using "drive couplings" and a "drive cap". "Drive
Foot
Valve
Step 4. Mount the pump as close to the well as possible.
Step 5. If one well point does not supply enough water, consider
All Shallow Well Installations
Suction Pipe
Step 6. Install a priming tee, priming plug, and suction pipe to the pump
From Well
Priming
Tee and
Plug
Check
Valve
Drive
Coupling
Step 7. Run piping from the discharge tee in the tank flange to the household
Drive
Point
You have just completed the piping for your new pump/tank system .
Please go to Page 9 for electrical connections .
5988 0409
1" NPT close nipple, a 1"x1"x3/4" NPT Tee, and a 1" NPT pipe
plug (see Figure 1). Install the pressure gage in the plugged hole in
the pump body (see Figure 4).
Align the venturi with the top hole on the front of the pump (see
Figure 6).
from the well to the pump suction port, using the fewest possible
fittings – especially elbows – as fittings increase friction in the pipe.
sure that the foot valve works freely.
the bottom of the well. It should also be at least 10 feet below the
well's water level while the pump is running in order to prevent the
pump from sucking air. Install a sanitary well seal.
fittings" are threaded all the way through and allow the pipe ends
to butt against each other so that the driving force of the maul is
carried by the pipe and not by the threads. The ordinary fittings
found in hardware stores are not threaded all the way through
the fitting and can collapse under impact. "Drive fittings" are
also smoother than standard plumbing fittings, making ground
penetration easier.
connecting two or three well points to one suction pipe.
(see Figures 7 and 8). Connect the pipe from the well to the pump
suction port, using the fewest possible fittings – especially elbows –
as fittings increase friction in the pipe.
• T he suction pipe should be at least as large as the suction port on
the pump (include a check valve – see Figures 7 and 8).
• S upport the pipe so that there are no dips or sags in the pipe,
so it doesn't strain the pump body, and so that it slopes slightly
upward from the well to the pump (high spots can cause air
pockets which can air lock the pump).
• S eal the pipe joints with Teflon™ tape or Teflon-based™ pipe
joint compound. Joints must be air- and water-tight. If the suction
pipe can suck air, the pump cannot pull water from the well.
piping. The discharge piping must be at least as large as the tank
tee. Install a relief valve in the discharge pipe capable of passing the
entire pump flow at 75 psi. Run a pipe from the relief valve to a floor
drain or some other convenient place to carry off the water.
or Larger Casing
"
7