The Digital Control Center system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
LG – ELECTRIC REQUIREMENTS
230V, 3.3AMP, 50HZ, 275W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety
testing and certification services, comply with a testing
tolerance of ± 5-10 percent.
GRILL PROBE SPADE
CONNECTORS
S
N
S
N
GRILL PROBE
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
300W, 230V, 2.6AMP,
9.5MM x 127MM (0.375" x 5.000")
INDEX
W : WHITE
K : BLACK
Y : YELLOW
N : BROWN
B : BLUE
S : SILVER
R : RED
G : GREEN
ELECTRICAL WIRE DIAGRAM
TEMPERATURE
SETTING SWITCH
°F
°C
DIGITAL CONTROL CENTER
°F
K
R
B
Y
W
°C
CONNECTOR BOX (8 PIN)
K
R
B
Y
W
W
R
W
W
Y
AUGER FEED SYSTEM
230V, 50/60HZ,
30W, 0.5AMP,
2 RPM MOTOR
HOPPER ACCESS PANEL
LOCATE AND REMOVE THE
EIGHT SCREWS ON SIDE
OF HOPPER TO ACCESS
ELECTRICAL COMPONENTS
FAST-BLOW FUSE
5 AMP
WIRE HARNESS
CONNECTOR BOX
W
W W
W
W
W
K
B
W
W
W
B
W
B
GROUNDED
POWER CORD
GROUND
G
COMBUSTION & COOLING FAN
230V, 50/60HZ, 0.21/0.19AMP,
CFM110, 1 PHASE