FUSE CHECK/REPLACEMENT
1.
Disconnect the battery connector (12).
2.
Move aside the recovery water drain hose (16).
3.
Remove the battery charger cable (I, Fig. 6) from the holder (J).
4.
Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the panel (B).
5.
Check/replace the following fuses:
C)
F1 fuse, deck: (40 A)
D)
F2 fuse, vacuum system: (30 A)
E)
Drive system fuse F3: (30 A) (*)
F)
F4 fuse, signal circuits: (3 A)
G)
Brush/pad-holder release fuse F5: (20 A) (*)
H)
Pump fuse F6: (3 A) (*)
(*)
Only for Adfi nity™ X20R
6.
Perform steps 1 to 4 in the reverse order.
DETERGENT TANK CLEANING
(For Adfi nity™ X20R)
Clean the detergent tank (45) according to the following procedure:
1.
Drive the machine to the appointed disposal area.
2.
Open the cover (22) and check that the recovery tank (21) is empty, otherwise empty it with the drain hose (16). Close the
cover (22).
3.
Grasp the handle (41) and carefully lift the tank (40).
4.
Unscrew the plug and disconnect the hose (48) from the tank (45).
5.
Remove the tank by releasing it from the fasteners.
6.
Wash the tank in the appointed disposal area.
7.
Install the tank (45) and connect it to the hose (48).
8.
When the detergent tank has been drained, the EcoFlex™ system must be drained too (see the procedure in the following
paragraph).
A
F G H
A
J
I
Adfi nity™ 17ST - 20ST - X20R
INSTRUCTION FOR USE
A
B
D
E
A
K
Figure 7
9096912000(4)2010-11
ENGLISH
C
23
S311339