Troubleshooting guide
In the unlikely event that a problem occurs on the equipment, this troubleshooting guide can be used to identify the probable cause
and remedy.
Troubleshooting should only be attempted by competent personnel. All major repair, and calibration work should be
undertaken by a domnick hunter trained, qualified and approved engineer.
Warning
Problem
Poor dewpoint identified by water in
the downstream piping and equipment.
High pressure drop resulting in low
pressure gauge readings or
intermittent operation of the
downstream equipment.
Interruption of the air supply
downstream leading to a rapid loss
of system pressure.
Possible cause
Dryer is operating outside of its
sizing criteria.
Bypass valve is open.
Dryer has recently been started.
The condensate is not being
drained.
Regeneration column pressure >
350mbar.
Timer malfunction.
Valve malfunction.
Desiccant is approaching the end
of its useful life.
The pre / after filtration is approaching the
end of its operational life.
The dryer is being overflowed or is
operating at a reduced system
pressure.
An isolation valve is partially
closed.
Pressure loss from the system.
Compressor switched off.
13
Action Required.
Check actual inlet parameters and
environmental conditions against the
values quoted at the time of sizing.
Check bypass valve is fully closed.
Allow time for the system to "dry
down"
Check the condensate drain(s) for
faults.
Check the drain hoses are free from
kinks and obstructions.
Ensure that the drain isolation valves
are fully open.
Replace the exhaust silencers.
Contact domnick hunter approved
service agent.
Contact domnick hunter approved
service agent.
Contact domnick hunter approved
service agent.
Check and replace.
Check actual inlet conditions against
the values quoted at the time of
sizing.
Check the position of all the isolation
valves.
Check the system for leaks.
Ensure that the drain cocks and
pressure relief valves are closed.
Check the compressor.