Operation Instructions
CONNECTING THE GRILL TO THE NATURAL GAS SUPPLY:
The quick disconnect socket (E1) and supply gas line must be installed by a qualified service
agency. The supply connection must be made in accordance with local codes or, in the absence
of local codes, with either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, in the USA, of the
Natural Gas and Propane Installation Code, CSA B149.1, in Canada.
A properly sized manual shut-off valve must be installed between the frill and the gas supply piping.
The grill and its individual shut-off valve must be disconnected from the gas supply piping system
The grill must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than 0.5 PSI (3.5 kPa).
valve.
To Connect:
1. Ensure that the natural gas shut-off valve is closed.
2. Remove the protective rubber caps from the plug and
sleeve ends of the quick disconnect fittings. Check that
the fittings are clean.
3. Retract the sleeve on the coupling as illustrated.
4. Insert the plug and release the sleeve as illustrated.
5. Push the plug into the sleeve until the sleeve snaps
forward to lock the plug in the coupling.
6. Open the natural gas shut-off valve.
To Disconnect:
1. Close natural gas supply at shut-off valve.
2. Push the sleeve back and gently pull out the plug.
3. Replace the protective rubber caps on the plug and sleeve
ends of the quick disconnect couplings.
In the connection process, make sure:
WARNING
16
Retract sleeve
Release sleeve
E1