G
B
Reduced gas flow rate setting for hob taps
1. Ignite the burner that is to be adjustment and turn the knob to the
reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust the flow rate adjustment
screw. For LPG (butane-pro pane) turn the screw clockwise. For the naturel
gas, you should turn the screw counter- clockwise once.
"The normal length of a straight flame in the reduced position should
be 6-7 mm."
4. If the flame is higher then the desired position, turn the screw clockwise.
If it is smaller turn anticolockwise.
5. For the last control, bring the burner both to higt-flame and reduced
positions and check whether the flame is on or off.
Depending on the type of gas tap used in your appliance the adjustment
screw position may vary.
To adjust your oven acc. to the gas type, make the adjustment for reduced
flame carefully by turning with a small screwdriver as shown below on the
screw in the middle of the gas cocks as well as nozzle changes (figure 6 and
7).
Figure 6
26
Figure 7