Sokkia SET300 Manual Del Operador página 105

Instrumento topográficos
Tabla de contenido

Publicidad

d) Backsight station Z coordinate
6. Instrument and target heights, temperature, pressure and ppm output (De)
De 12.345, 1.500, -20, 1015, -39 [,SUM] CR LF
a
b
a) Data identifying code
b) Instrument height
c) Target height
d) Temperature
e) Pressure
f)
ppm
7. Coordinates setting-out data output (Df)
Df 1234.567, -12.345, 9.182 [,SUM] CR LF
a
b
a) Data identifying code
b) Setting-out N coordinate
c) Setting-out E coordinate
d) Setting-out Z coordinate
8. Slope distance, Vertical, Horizontal, angle data output (Ea)
Ea 0000, 0, 1.500, -199, 9.999, 89.5959, 359.5959 [,SUM] CR LF
a
b
c
a) Data identifying code
b) Status
The digit signifies in order,
Distance units 0: meters (1: feet), Angle units (0: degree, 1: gon, 2: mil),
Vertical angle display (0: Zenith 0°, 1: Horizontal 0°, 2: Horizontal ±90°),
Horizontal angle display (0: Right , 1: Left)
c) Always 0
d) Target height
e) ppm
f)
Slope distance
g) Zenith angle (vertical angle)
h) Horizontal angle
9. Horizontal distance, Vertical and Horizontal angles data output (Eb)
Eb 0000, 0, 1.500, -199, 99.999, 89.5959, 359.5959 [,SUM] CR LF
a
b
c
23. DETAILS OF DATA INPUT / OUTPUT
c
d
e
f
c
d
d
e
f
d
e
f
g
h
g
h
99