23. DETAILS OF DATA INPUT / OUTPUT
a) Data identifying code
b) Status (for explanation, see 8) Ea)
c) Always 0
d) Target height
e) ppm
f)
Horizontal distance
g) Zenith angle (Vertical angle)
h) Horizontal angle
10. Height difference, Vertical and Horizontal angles data output (Ec)
Ec 0000, 0, 1.500, -199, 99.999, 89.5959, 359.5959 [,SUM] CR LF
a
b
c
a) Data identifying code
b) Status (for explanation, see 8) Ea)
c) Always 0
d) Target height
e) ppm
f)
Height difference
g) Zenith angle (Vertical angle)
h) Horizontal angle
11. N, E, Z coordinates output (Ed)
Ed 0000, 0, 1.500, -199, 123.456, 234.567, 1.234 [,SUM] CR LF
a
b
c
a) Data identifying code
b) Status (for explanation, see 8) Ea)
c) Always 0
d) Target height
e) ppm
f)
N coordinate
g) E coordinate
h) Z coordinate
12. Vertical, Horizontal, X-tilt, Y-tilt angles data output (Ee)
Ee 0000, 0, 1.500, -199, 89.5959, 359.5959, -0.0032, 0.0216 [,SUM] CR LF
a
b
c
a) Data identifying code
b) Status XXXX (for explanation, see 8) Ea)
100
d
e
f
d
e
f
d
e
f
g
h
g
h
g
h
i