ELECTRICAL WIRING
230V ~ 50Hz
L
N
7 pin plug
1
N T1 T2 S3 B4
7 pole socket
N
1
2
3
Valve
Black
CONTROL BOX
- To remove the control-box from the burner,
loosen screw (A) (see figure) and pull towards
the arrow.
- The flame sensor is fitted directly into the control-
box (underneath the ignition-transformer) on a
plug-in support.
2351
Switch with fuse
6A max.
Hour counter
h
Remote lock-out lamp
(230V - 0.5A max.), if required
L
4
5
6
7
M
~
Black
Capacitor
Motor
WARNING
Do not exchange the neutral with the phase
NOTES:
– Wires of 1 mm
– The electrical wiring carried out by the
installer must be in compliance with the
rules in force in the Country.
TESTING
Check the shut-down of the burner by opening
the thermostats.
Regulating thermostat
T
Limit thermostat
T
with manual resetting
TERMINAL
BLOCK OF
8
9
CONTROL-BOX
530SE *
S7183
D5334
RUN OF THE ELECTRICAL CABLE
1 - Grommet
2 - Cable-clamp
3 - Terminal block
ATTENTION
Do not connect burner's grounding, to fail-
ure indicator terminal
the destroy of the control box.
5
GB
2
section.
N - Neutral
L - Phase
- Burner-earth
- Lock-out lamp
. This may result