Descargar Imprimir esta página

Orbegozo DS 59160 IN Manual De Instrucciones página 18

Publicidad

Idiomas disponibles

Idiomas disponibles

DS 59160 IN / DS 59190 IN
4.7 Fix the hook to the wall and install the plate.
4.8 Fix the one-way valve with the screws supplied, add the reductor and the soot tube, and draw it
outwards (see Figure B).
4.9 Place on the wall (Figure C).
4.10 Calculate the final height of the U-shaped section and pull the inside of the U-shaped section up to
the correct height.
4.11 Secure the template in the lower tube using the screws supplied to mark out and drill two 8 mm holes
in the wall (Figure D).
4.12 Finally, drill two 8 mm holes in a suitable p lace in line with the second plate (Figure E) and tighten the
two screws.
THE CLASS 1 HOOD MUST BE EARTHED
The connection should be made as follows;
BROWN
BLUE
YELLOW/GREEN
THE CLASS 2 HOOD MUST NOT BE EARTHED
Second class hoods with the characteristics label containing the double square symbol.
The connection should be made as follows;
=
L (live)
=
N (neutral)
=
Earth
18

Publicidad

loading

Este manual también es adecuado para:

Ds 59190 in