Descargar Imprimir esta página

Riello RS4D Instrucciones De Instalación, Uso Y Mantenimiento página 10

Quemadores de gas con aire soplado

Publicidad

Idiomas disponibles

Idiomas disponibles

4.4
Technical data
Model
Thermal power
(1)
Fuel
Operation
Use
Ambient temperature
Combustion air temperature
Noise levels
Sound pressure
(2)
Sound power
Weight
Reference conditions: Temperature 20°C - Barometric pressure 1013 mbar – Altitude 0 m above sea level.
(1)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum output. The sound
(2)
power is measured with the "Free Field" method, as per EN 15036, and according to an accurate "Accuracy: Category 3" measurement, as
described in EN ISO 3746.
4.5
Electrical data
Model
Electrical power
Fan motor
Ignition transformer
Capacitor
Absorbed electric power
Protection level
20141174
Technical description of the burner
RS4D
kW
110/140 ÷ 246
Mcal/h
94.6/120.4 ÷ 211.6
Gas G20
°C
°C max
67
dB(A)
78
kg
20
RS4D
1 230V 50 Hz
rpm
2720
Hz
50
A
1,9
F
kW
0,53
8
RS5D - RS5D TL - RS5DF
3
NCV 8  12 kWh/m
– 7.000 10.340 kcal/m
Pressure: min. 20 mbar – max. 100 mbar
Intermittent (FS1)
Boilers: water and diathermic oil
0 - 40
40
RS5D - RS5D TL
1~ 230V 50 Hz
1~ 220/230V 50 Hz 1~ 220/230V 60 Hz
2720
50
1,9
Primary 230V
Secondary 18 kV / 11 mA
8,0
0,45
IP40
GB
160/208 ÷ 345
137.6/178.8 ÷ 296.7
3
70
81
18 - 20
RS5DF
2720
3320
50
60
1,9
2,3
0,45
0,62
Tab. C
Tab. D

Publicidad

loading

Este manual también es adecuado para:

Rs5dRs5df37618663762016376205820052615 ... Mostrar todo