Technical data
Parameter
Voltage
Power
Power (EN 60335-2-69) (*)
Weight
Noise level (Lpf) (EN60335-2-69)
Protection
Insulation
Capacity
Inlet
Vibration, a
(**)
h
Max vacuum
Max. air flow rate without hose and
reductions
Max. air flow rate (3 m Ø 50 mm hose)
Hoses allowed for classes "L" and
"standard"
Hoses allowed for classes "M" and "H"
Main filter surface (L-M)
Upstream Hepa filter H surface (cod.
17050)
Downstream Hepa filter surface (cod.
17092)
Hepa filter efficiency according to MPPS
method (EN 1822)
(*)
Measurement uncertainty KpA <1.5 dB(A). Noise emission values obtained according to EN-60335-2-69
(**) Total value of vibration output to the operator arm and hand
Dimensions
Model
3707
A (mm)
1.600
B (mm)
800
C (mm)
1.810
Weight (kg)
291
[ NOTE ]
■
Storage conditions:
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
■
Operating conditions:
Maximum altitude: 800 m
(Up to 2,000 m with reduced performances)
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
04/2017
Units
3707
V
230/400/50
kW
5.5
kW
—
kg
291
dB(A)
78
IP
55
Class
F
L
175
mm
100
m/s
≤2.5
2
mm H
0
3,600
2
L/m'
8,100
L/m'
—
mm
100
mm
70
m
3.5
2
m
12
2
m
17
2
%
99.995 (H14)
Figura 3
3707/10
3907
1.600
1.600
800
800
1.810
1.810
305
411
3707 - 3907 - 3907 L, M, H - 3907/18 - 3907/18 L, M, H
3707/10 - 3707/10 L, M, H - 3907 W - 3907 W L, M, H
3707/10
3907
3707/10 L, M, H
3907 L, M
230/400/50
230/400/50
7.5
11
5
6
305
411
78
78
55
55
F
F
175
175
100
100
≤2.5
≤2.5
2,500
4,400
13,500
8,400
9,100
8,100
100
100
70
70
3.5
3.5
12
12
17
17
99.995 (H14)
99.995 (H14)
3907W
3907/18
1.600
1.600
800
800
1.810
1.810
324
360
7
3907 W
3907/18
3907 W L, M, H
3907/18 L, M, H
230/400/50
230/400/50
11
13
6
10
324
360
78
78
55
55
F
F
175
175
100
100
≤2.5
≤2.5
3,000
3,000
15,300
18,600
10,500
12,000
100
100
70
70
3.5
5
12
12
17
17
99.995 (H14)
99.995 (H14)
C65
GB