5.7 - REPLACING THE FLAPS

5.7.1 - Outer side flaps
To replace the side flaps pos. 1 Fig. 8, remove the rear wheels and the
relevant side guards. Loosen the screws that secure the flaps to frame
pos. 2 Fig. 8 and replace the old flaps with new ones.
5.7.2 - Inner side flaps
To replace the inner side flaps pos. 5 Fig. 8, lift the front part of the
machine and loosen screws pos. 6 Fig. 8 that secure the flaps to the
frame. Replace the old flaps with new ones.
5.7.3 - Centre flaps
- Remove the rear wheels and the relevant side guards.
- Remove the rear door.
- Loosen the two two flap fixing pins pos. 3 Fig. 8, located on the sides
of the frame.
- Grasp flap pos. 4 Fig. 8 and pull it outwards.
Remounting:
- Fit the flaps in the same direction in which they are removed.
- Insert the two references in their holes.
- Tighten the two fixing pins and reassemble the machine.

5.8 - REPLACING THE TRACTION CABLE

5.8.1 - Remove the traction cable as follows
To replace the traction cable proceed as follows:
- Remove the upper bonnet of the machine.
- Loosen the security dowel located on the cable fixing pin.
- Pull the cable out of the fixing pin and remove the adjusting screw
mounted on the handle.
- Press the handle and pull the cable out of its sheath.
To remount the cable:
- Fit one end of the cable into the adjustment screw of the handle (i.e.
the end without the blocking ball).
GB
10
ENGLISH (Translation of original instructions)
- Insert the cable into its sheath.
- Hook the blocking ball to the handle.
- Slot the cable through the turned adjustment screw secured to the
machine frame and then through the fixing pin.
- Tighten the security dowel.
The position of the cable is adjusted by acting on the two adjustment
screws.
5.8.2 - Replacing the side brush lifting cable
To replace the side brush lifting cable, proceed as follows:
- Remove the upper bonnet and the front bin of the machine.
- Remove the front bumper, the right wheel and the right hand side
guard.
- Loosen the cable clamp.
- Loosen the security dowel on the fixing pin.
- Remove thehandle from the support and open it up.
- Pull the cable out of the two sheaths.
To remount the cable:
- Put the cable inside the handle.
- Close up the handle and fix it to its support.
- Insert the cables into their sheaths.
- Secure one end of the cables in place with the clamp and the other end
with the fixing pin.
The position of the cable is adjusted by acting on the two adjustment
screws.
5.9 - REPLACING MOTOR FAN
(Electrical version)
To replace the motor fan proceede as follows:
- Remove the top bonnet.
- Disconnect the battery cables and take the battery out of the machine.
- Disconnect the power supply coders of the motor from the plug.
- Remove the stop for the cable holder from the motor.
- Loosen the four motor fixing screws.
- Replace the motor by carrying out the above operations in reverse
order.
Make sure the motor is mounted level with the fan.
IMPORTANT: WHEN CONNECTING THE MOTOR RE-
SPECT THE POLARITY.