Installing your thermostat
Alternate wiring key (heat pump system only)
1
Do not use K terminal. For future use.
If old thermostat has separate wires on AUX and E, place both wires into the E/AUX
2
terminal. If old thermostat has wire on AUX with a jumper to E, place wire on E/AUX
terminal. No jumper is required.
If your old thermostat had an O wire and not a B wire, attach the O wire to the O/B
3
terminal.
4
If your old thermostat had separate O and B wires, attach the B wire to the C terminal. If
another wire is attached to the C terminal, check honeywellhome.com/wifi-thermostat for
help. Attach the O wire to the O/B terminal.
5
If your old thermostat had separate Y1, W1 and W2 wires, check honeywellhome.com/wifi-
thermostat for help.
If your old thermostat had both V and VR wires, check honeywellhome.com/wifi-
6
thermostat for help.
7
Leave metal jumper between R and RC terminals in place.