Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Generator ................................................ Inverter
Protection type: ........................................ IP 23M
Continuous rated power P
..................................................... 3200 W/230 V~
Maximum power P
max
Rated voltage U
: ................. 230 V~/2x 5V/12V
rated
Rated current I
: ........ 13.9A (230V~)/2.1A (5V)/
rated
............................................................ 8.3A (12V)
Frequency F
: .......................................... 50 Hz
rated
Drive engine design: ..............4-stroke, air-cooled
Displacement: ......................................... 212 cm³
Max. power: ..................................4.3 kW / 5.9 hp
Fuel: ....................... normal unleaded petrol (E10)
Tank capacity: ................................................8.3 l
Engine oil: .............................................. ca. 0.55 l
Consumption at 2/3 load: ............. approx. 1.26 l/h
Weight: .....................................................47.5 kg
Sound pressure level L
Sound power level L
WA
............................................ 90 dB (A)/1.36 dB(A)
Power factor cos ϕ: ........................................... 1
Power class: ....................................................G2
Max. temperature: ....................................... 40°C
Max. altitude (above mean sea level): ..... 1000 m
Spark plug: ......................................... LG F6RTC
Operating mode S1 (continuous operation)
The machine can be continuously operated with
the quoted power output.
Operating mode S2 (temporary operation)
The machine may be temporarily operated with
the quoted power output (5 min.). Afterwards the
machine must be stopped for a while to prevent it
from overheating (5 min.).
Anl_TE_IG_3500_SPK13.indb 21
Anl_TE_IG_3500_SPK13.indb 21
(S1): .......................
rated
(S2 5 min): . 3300 W/230 V~
: ................... 68.5 dB(A)
pA
: K uncertainty ...................
GB
5. Before starting the equipment
5.1 Electrical safety:
•
Electric supply cables and connected equip-
ment must be in perfect condition.
•
The generator is to be operated only with
•
equipment whose voltage specifications con-
form with the generator's output voltage.
•
Never connect the generator to the power
supply (socket-outlet).
•
Keep the cable length to the consumer as
short as possible.
5.2 Environmental protection
•
Dispose of soiled maintenance material and
•
operating materials at the appropriate collec-
tion point.
•
Recycle packaging material, metal and plas-
tics.
5.3 Connecting to earth
The housing is allowed to be connected to earth
in order to discharge static electricity. To do this,
connect one end of a cable to the earth connec-
tion on the generator and the other end to an ex-
ternal earth (for example an earthing rod).
5.4 Battery
Caution! Whenever you do any work on the
battery and when you dispose of the battery, you
must observe the safety instructions of the manu-
facturer.
Warning! The person entrusted with inserting the
battery should remove all metal armbands, wrist-
watches, rings and similar before starting to insert
the battery. There is a risk of burns if any of these
objects should come into contact with the battery
poles or current-conducting cables.
Warning! Check the insulation on the cables
and plugs each time before use. If there are any
defects in the insulation, the equipment must not
be used.
Warning! Have repairs carried out only by an au-
thorized workshop or by the manufacturer.
- 21 -
22.06.2022 08:42:23
22.06.2022 08:42:23