Descargar Imprimir esta página

IPC 2360T-DS Manual De Instrucciones página 25

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
Before carrying out any operations, disconnect the water cleaner from the mains electricity supply via the omni-
!
FAULTS
When the switch is turned the cleaner
does not start.
No jet delivered.
The pump turns but does not reach
the rated pressure.
When the lance is turned on the pres-
sure falls and rises.
After 10 pulses,
the water cleaner stops and indicator
light "D" (fig. 6) flashes.
In by-pass or total stop phase, the wa-
ter cleaner shuts down and indicator
light "D" (fig. 6) flashes.
After the total stop phase, the water
cleaner does not start up and the indi-
cator lights is on.
When the thermostat reaches the
chosen temperature the boiler does
not light.
Indicator light "F" (fig. 6) flashes.
Water not hot enough.
Too much smoke from the flue.
Insufficient detergent suction.
English
TROUBLE-SHOOTING
polar switch or by unplugging the plug from the socket.
CAUSES
Faulty electric connection.
Thermal protection has tripped.
Faulty water circuit connection.
Clogged water filter.
Mains tap turned off.
Detergent tap turned on.
Water intake filter blocked.
Faulty water circuit connection.
Pressure regulation valve is set at
minimum.
Lance nozzle is worn.
Dirty or worn valves.
Detergent intake device on the lance is
turned on.
The nozzle is clogged or deformed.
Insufficient supply.
Micro-leaks of water from the high pres-
sure circuit.
The water cleaner has been unused for
at least 20 minutes and is in a state of
total shutdown.
No fuel.
Fuel filters are clogged.
Thermostat setting.
Clogged filters.
Boiler coil clogged with scale.
No fuel.
Incorrect combustion.
Impurities or water in the fuel.
Tap turned off.
No detergent in the tank.
Control on the lance not switched on.
Coil or pipe clogged.
- 25 -
REMEDIES
Check the mains voltage.
Reset (if it trips again, apply to the
technical service centre).
Check it.
Clean it.
Turn it on.
Turn it off.
Clean it.
Check it.
Regulate it.
Apply to our technical service centre.
Apply to our technical service centre.
Turn it off.
Clean or consult our technical service
centre
Check it.
Contact Service Centre.
Restart by rotating the main switch "A"
(fig. 6) into the "O" position and subse-
quently into the "I" position.
Check the fuel level in the tank and see
that the fuel intake circuit is clean (no
water).
Change the in-line filter.
Check it.
Clean the fuel filters.
Apply to our technical service centre.
Fill the fuel tank.
Clean the various fuel filters.
Empty the tank and clean it carefully.
Clean the various fuel filters too.
Turn it on.
Fill the detergent tank.
Set the control on the lance.
Apply to our technical service centre.

Publicidad

loading

Este manual también es adecuado para:

2960t-dsDs 1530mDs 2360t ds 2575tDs 2960tDs 2280tDs 2280t-gt ds 2880t