How to Wire Your Ceiling Fan (continued)
WARNING
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors except for the ground wire. Do not
operate fan until the blades are in place. Noise and
motor damage could result.
5. After connections have been made, turn leads
upward and carefully push leads into the outlet box,
with the white and green leads to one side of the
box and the black leads towards the other side.
The wires should be spread apart with the
grounded conductor and the equipment-grounding
conductor on one side of the outlet box and the
ungrounded conductor on the other side of the
outlet box (Figure 6).
How to Install Your Canopy Housing
1. Remove one of the two shoulder screws in the
hanger bracket. Loosen the second shoulder screw
without fully removing it. Assemble canopy by
rotating key slot in canopy over shoulder screw in
hanger bracket. Tighten shoulder screw. Fully
assemble and tighten second shoulder screw that
was previously removed (Figure 1).
WARNING
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the canopy
housing and not pinched between the housing and
the ceiling.
2. Securely attach and tighten the canopy screw
cover over the shoulder screws in the hanger
bracket utilizing the keyslot twist-lock feature
(Figure 2).
HARDWARE USED:
WIRE
CONNECTORS
LISTED OUTLET BOX
BLACK-ANT
Figure 6
SHOULDER
SCREWS (2)
8
x 6
WHITE
BLACK
BLUE
GREEN - Ground Wire
From Hanger Ball
GREEN - Ground Wire From
Hanger Bracket
CANOPY
Figure 1
CANOPY COVER