• Check the duct condition
TM
If the Flow Sense
LED is turned on, check the
exhaust system for restrictions and damage. Repair
or replace the exhaust system as needed.
NOTE
When the dryer is first installed, this test should
be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during normal
operation provides more accurate information on
the condition of the exhaust duct than does the
installation test, the number of bars displayed
during the two tests may not be the same.
Do not interrupt the test cycle, as this could result
in inaccurate results.
Even if no bars are displayed during the test
cycle, some restrictions may still be present in the
exhaust system. Refer to the Venting the Dryer
section of this manual for complete exhaust
system and venting requirements.
Your dryer features Flow Sense™, an innovative
sensing system that automatically detects
blockages and restrictions in the dryer ductwork.
Keeping ductwork clean of lint buildup and free
of restrictions allows clothes to dry faster and
reduces energy use.
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or bends.
Excess or crushed
transition duct
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or restricted.
INSTALLATION
33
Too many elbows or
exhaust too long
Lint
buildup or
blockage
Crushed
or
damaged
exhaust