The equipment must only be operated by qualified specialized
staff!
Unit is intended for operator professionally well trained, he must know refrigeration foundamen-
tals, cooling systems, refrigerants and possible damages that equipments under pressure could
cause.
Read carefully instructions in the literature, strict observance of procedures is main condition for
operator safety, constant declared performances and unit undamaging.
Wear safety glasses and gloves when handling refrigerant; avoid contact with refrigerant, blind-
ness and injuries may result to operator.
Keep away from flames and hot surfaces; high temperature decomposes refrigerant releasing
toxic contaminants very dangerous for environment and operator.
Avoid skin contact; refrigerant has a very low boiling temperature (approx. -18°C / -3°F) and
freezing may occurs.
Avoid inhaling vaporized refrigerant gas; it has a narcotic effect.
Vacuum pump must always be suitably earthed.
Even if the pump temperature is not expected to rise a high level during use, it is advisable to lo-
cate the unit so that users cannot make contact with the casing, as burns may result.
Vacuum pump is air cooled with integral fan; use only where air can freely circulate.
During operations, do not vent refrigerant in environment.
2
Material included
1 x Vacuum pump
1 x Cable
1 x Mineral oil bottle
1 x Connector 1/4" SAE – F – 5/16" SAE – M
1 x Connector 1/4" SAE – F – 3/8" SAE – M
1 x Instructions for use
3
Technical Data
Voltage .............................................................. 230 V, 50/60 Hz ........... 230 V, 50/60 Hz
Flow rate ...................................... 50 Hz ............ 1,2 cfm/ 34 l/min ........... 5,0 cfm/ 142 l/min
Final vacuum ..................................................... 15 micron ..................... 15 micron
Power ................................................................ 190 W .......................... ¾ PS/ 0,55 kW
Refrigerant classes ............................................ A1, A2L, A2 .................. A1, A2L, A2
Inlet ................................................................... ¼" SAE ........................ ¼" SAE
Oil capacity ........................................................ 250 ml .......................... 580 ml
Dimensions (L x W x H, mm) ............................. 310 x 150 x 220 ........... 395 x 170 x 270
Weight ............................................................... ca. 10,1 kg ................... ca. 17,3 kg
Protection type ................................................... IP 44 ............................ IP 44
Noise pressure level dB (A) L
Sound power level dB (A) L
The noise level during operation can exceed 85 dB (A). Wear ear protection!
Measured values determined in accordance with EN 60335-1.
14
ROAIRVAC R32 1.5
60 Hz ............ 1,5 cfm/ 42 l/min ........... 6,0 cfm/ 170 l/min
¦ K
.................. ≤ 60 ¦ 3 ......................... ≤ 68 ¦ 3
pA
pA
¦ K
................... ≤ 71 ¦ 3 ......................... ≤ 79 ¦ 3
WA
WA
ENGLISH
ROAIRVAC R32 6.0