Note
The unit has a 60-second overrun. When the set
temperature is reached or the heater is set to standby
mode by pressing the function key
nues to run for 60 seconds to cool down the unit.
Switch on oscillation
To switch on oscillation in addition to a heating level
or ventilation mode, press the oscillation function key
. To deactivate the function, press the button again.
4
Note
The oscillation mechanism must never be adjusted
manually. It could be damaged. Only use the function
button
provided for this purpose.
4
Set switch-off timer
You activate the timer for switching off while the unit
is already in operation. Proceed as follows to set the
desired time period for switching off:
1. Press and hold the mode button
seconds. Now the LED display
after the appliance is to switch off instead of the
°C display.
2. Use the function buttons
desired number of hours. Confirmation is not
necessary. The number of hours you have selec-
ted flashes and the display automatically changes
back to the °C display after your selection.
Note
When the timer is activated, the appliance should
never be operated unattended in a freely accessible
room.
Switch off the unit
1. Put the unit into standby mode by pressing the
function button
3
2. Let the fan run to the end to cool down the unit.
3. Switch off the appliance by setting the main
switch
to 0.
12
4. Pull the mains plug out of the socket.
5. Let the appliance cool down completely.
22
, the fan conti-
3
for a few
5
shows the hours
7
and
to set the
1
2
.
Troubleshooting
Problem
Cause
Unit does not have
power supply
Unit, mains cable
or mains plug is
defective
The room tempe-
rature is above the
temperature set on
the thermostat.
No heating level set
Unit without
function/not
heating
The anti-tilt
protection has been
triggered
The safety thermo-
stat has tripped
The overheating
protection has been
triggered
Reduced air
Air inlet and outlet
flow
not free
Note
After all troubleshooting, maintenance and cleaning
work, wait at least 5 minutes before switching the unit
on again.
If the unit still does not work properly, please contact
the customer service or an authorised electrician. The
unit must then be checked and repaired if necessary.
Solution
Check the socket
Plug in the mains
plug correctly
Check the house
fuse
Contact customer
service or a spe-
cialist
Increase the ther-
mostat tempe-
rature
Adjust the heat
level
Make sure the
appliance is positi-
oned vertically and
is not exposed to
extreme inclination
Switch off the unit
and disconnect the
mains plug.
Eliminate the cause
of overheating
before restarting
the appliance.
Switch off the unit
and disconnect the
mains plug.
Contact customer
service or a spe-
cialist
Clean and observe
minimum distances