Recording Data (cont'd)
Viewing Stored Recordings
1. Set the rotary switch to MR.
2. The instrument displays the last recording stored in the instrument. The secondary (top)
display indicates the memory location; while the main display indicates the measured value.
To see the other measurements, press the p button. The record number is decremented
and the corresponding measurement is displayed.
3. To scroll rapidly through the recorded measurements, keep the p button pressed.
4. To select a specific recording, use the u button to change the recording number.
5. Once you select the recording number, you can see all information associated with the
measurement. Press the MEM button for >2 seconds, then use the p button to scroll the
information.
6. When finished viewing recordings, press MEM for >2 seconds.