11. If the power cord is damaged, it must be replaced by the manufacturer, its after-sales service or similar qualified person-
nel in order to avoid any malfunction.
12. The light source of this luminaire must only be replaced by the manufacturer, its technical service or a qualified person.
Note: The important warnings and instructions indicated in this manual are not guaranteed to cover all possible conditions
and situations that may occur. It must be understood that common sense, precaution, and care are factors that cannot be
included in all products. These factors can and must only be provided by the user who maintains and enjoys this fan.
Environmental protection
Do not throw away electrical products together with household waste. We ask you to recycle the packaging at the
collection points provided for this purpose. Contact local authorities or your provider for recycling advice. Thank you
for recycling at the collection points provided for this manual.
Device technical spectifications
Nominal voltage and frequency
Ampoule
Ampoule d'au maximum
mesurée
Classe de protection
Degré de protection
Température de travail
Régulable/Non-régulable
Inclinaison maximale du plafond sur lequel il peut être installé
Weight
Speed
Fan power (W)
Fan RPM
Fan airflow (m³/min)
Noise level (dB)
Preparing for installation
Note: The estimated installation time is 120 minutes. This product can only be installed by a certified electrician Carefully
separate the fan's parts, avoiding the use of cutters or blades that could scratch any part of it.
Remote control safety functions
Blocking protection
The remote receiver includes a function that automatically blocks motor operation, cutting current to the motor 30 seconds
after detecting an obstruction in front of the fan that prevents normal operation. When this happens, you must remove the
obstacles blocking the fan. Then, press the off button on the remote control to reset the receiver. Now you can continue to
use the fan normally.
Note: Unless you remove the obstruction blocking the fan, it will not operate correctly.
Overload prtection
If the fan's receiver detects that the motor is operating at greater than 80W (this indicates an overload), current to the motor
will be cut automatically, which will immediately stop the fan. To reset the receiver, press the off button on the remote control.
Note: If the receiver goes into protection mode again, this may indicate a motor defect. Contact the supplier immediately. The
duration of the warranty is indicated in the warranty document provided in this manual.
B
A
Installing a fan without a shaft, flush with the ceiling, can reduce airflow.
220-240V~AC 50Hz
Máx. 1x40W E27
A
60mm
B
100mm
Class I
IP20
-5 ↔ 40ºC
No dimable
15º
4,9kg
1
2
3
35
40
52
124
197
240
45
90
127
25
32
45
9