Troubleshooting
Always remove the battery before carrying out any work on the power tool.
Condition
Machine does not run when switched on
BGA 85
All manuals and user guides at all-guides.com
Cause
No electrical contact between power tool
and battery
Battery discharged
(1 light emitting diode on battery flashes
green)
Battery too hot / too cold
(1 light emitting diode on battery glows red)
Fault in battery
(4 light emitting diodes on battery flash red)
Power tool too hot
(3 light emitting diodes on battery glow red)
Fault in power tool
(3 light emitting diodes on battery flash red)
Moisture in power tool and/or battery
Remedy
Remove battery, check contacts and refit
battery
Charge the battery
Allow battery to cool down / Warm up bat -
tery slowly at a temperature of 60°F to
70°F (15°C–20°C).
Take the battery out of the power tool and
refit it. Switch on the power tool – if the
light emitting diodes still flash, the battery
is faulty and must be replaced.
Allow power tool to cool down
Take the battery out of the power tool and
refit it. Switch on the power tool – if the
light emitting diodes still flash, the power
tool is faulty and must be checked by a
1)
servicing dealer
.
Allow power tool/battery to dry