10 |
MULTILINGUAL
When the jumper settings are set to D1 and D2 the sensor is configured in the Home-
group. In full security mode the sensor will be enabled. If In-home security is activated
this sensor will be disabled.
It's possible to configure a delay for a sensor. This is set by the jumper setting D1 and
D3. This is the Single Group.
Remark : Sensors configured in the single group will be enabled in both security
modes (Full, In-home) after a specified time.
Sensors with a jumper setting of D0, D1 and D3 are configured as 24hours-group.
These sensors are always enabled regardless the status of the security system.
3.3 Registered sensors
The motion detector and window/door sensor included with the alarm system are
already paired to the system. The motion detector is set by default as Home-group
and the window/door contact is configured as Normal-group.
The window/door contact is paired with Zone 1. The motion detector is paired with
Zone 2.
3.4 Install the control panel
The control panel can be installed on the wall or can be placed on the table.
To install the control panel on the wall you will need to install the wall-mount to the
wall. To install the wall-mount use the supplied screws and plugs. After installing the
wall mount you can install the control panel to the wall-mount by inserting the pins on
the wall mount in the installation holes on the back of the control panel and slide the
device downwards. The wall-mount will secure the anti-sabotage button.
To install the control panel on the table install the table mount to the installation holes
on the back of the control panel. Make sure the anti-sabotage button is pressed before
installing the mount.