P SERIES 6X4 WARNING LIGHT
COLOR SWAP
This function is only valid for dual and tri-color warning light modules and can only be changed when the light module is in a flashing mode (disabled for single color modules and when light module is operating in cruise or steady ON functions).
When the light is flashing, momentarily connect the white wire to ground for >2S and <3S (light will go steady high, steady low, off) then release. The light module will switch between Color Swap OFF and Color Swap ON. When Color Swap
is OFF, the 1st color will flash 1st on a dual/tri color pattern. When Color Swap is ON, the 2nd color will flash 1st on a dual/tri color pattern.
SIMULTANEOUS/ALTERNATE
This function can only be changed when the LED module is in a flashing mode (disabled in cruise or steady ON functions) and only has an effect when at least 2 LED modules have the green sync wire connected together. When the light is
flashing, momentarily connect the white wire to ground for >3S and <4S (light will go steady high, steady low, off, steady high) then release. The light module will switch between Simultaneous and Alternate each time this sequence is done.
To have light modules flash simultaneously, both light modules need to be set to the same sequence type (Set-Up Table). To have light modules flash alternately, the light modules need to be set to different sequence types (Set-Up Table).
ADVANCE PATTERN
Flash pattern can only be changed when the LED module is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white wire to ground for >250mS and <1S (light will go steady
high) then release. The flash pattern will advance to the next pattern. If the light module was at the last pattern, the pattern will reset to the 1st pattern.
BACKUP PATTERN
This function is only valid when the LED module is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white wire to ground for >1S and < 2S (light will go steady high, steady
low) then release. The flash pattern will backup to the previous pattern. If the light module was at the first pattern, the pattern will change to the last pattern on the list.
PATTERN RESET
This function is only valid when the LED module is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white wire to ground for >5S and <6S (light will go steady high, steady low,
off, steady high, steady low, off) then release. The flash pattern will reset to the 1st pattern in the list.
FACTORY RESET
This function is only valid when the LED module is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white wire to ground for >6S and <7S (light will go steady high, steady low,
off, steady high, steady low, off, steady high) then release. The LED module will reset to: pattern=1, Function Table=1, Color Swap=OFF, Simultaneous.
LOCKOUT CONFIGURATION WIRE
This function will disable the wire tap configuration mode that is activated by holding the white wire to ground. The lock out is activated by applying ground to the white wire for >7 seconds and <8 seconds per the table below. The function
can be disabled by tapping the wire to ground and releasing 8 times within 5 seconds. The light will flash 8 times when the feature is enabled or disabled to notify the user of a setting change.
1.800.338.7337 / www.soundoffsignal.com
8
WIRING AND TABLE INFORMATION (CONT.)
SECONDS
FROM
TO
VISUAL FEEDBACK
0
1
STEADY-HIGH (60%)
1
2
STEADY-LOW (30%)
2
3
OFF
3
4
STEADY - HIGH (60%)
4
5
STEADY - LOW (30%)
5
6
OFF
6
7
STEADY-HIGH (60%)
7
8
STEADY - LOW (30%)
If held longer than 8 seconds, the light will go back to flashing the current pattern and no action will be taken.
SETUP TABLE
USER INTERFACE
ACTION TAKEN
FORWARD ONE PATTERN
BACKWARD ONE PATTERN
COLOR SWAP (OFF OR ON )
SEQUENCE TYPE:
SIMULTANEOUS OR ALTERNATE
SEE FUNCTION TABLE
RESET TO PATTERN 1
FACTORY RESET (PATTERN 1, COLOR SWAP: OFF, SIMULTANEOUS)
SEPARATE COLOR CONTROL: OFF
LOCK OUT WHITE CONFIGURATION WIRE
6X4 POLYCARB_WARNING 0422 REV C