Pump ranges
These operating instructions concern the following AIR-CENTER: LZA 2200 (01) to (08)
Equipment of the AIR-CENTER
LZA
with following components
KTA 100/1 + KTA 80/4 + KTA 80/1
2200 (01)
SAP 300
KTA 140/1 + KTA 80/4 + KTA 80/1
2200 (02)
SAP 300
KTA 100/1 + KTA 100/4 + KTA 80/1
2200 (03)
SAP 300
KTA 140/1 + KTA 100/4 + KTA 80/1
2200 (04)
SAP 300
KTA 100/1 + KTA 80/4 + KTA 80/1
2200 (05)
SAP 300 + SAP 180
KTA 140/1 + KTA 80/4 + KTA 80/1
2200 (06)
SAP 300 + SAP 180
KTA 100/1 + KTA 100/4 + KTA 80/1
2200 (07)
SAP 300 + SAP 180
KTA 140/1 + KTA 100/4 + KTA 80/1
2200 (08)
SAP 300 + SAP 180
Description
The AIR-CENTER is available in different sizes, dependent upon its internal components. Two large roof fans on the box provide intensive air
cooling of the built-in components. The fans are located behind a protecting grill. The cooling air flows through the box from bottom to top.
All components are equipped with dual frequency motors 50/60 Hz.
A distance installation of the AIR-CENTER is possible to corresponding capacity of dimension.
SAP 300
ZAF
SAP 180
ZAF
Applications for the AIR-CENTER
2 Colour printing press with or without 1 perfector
4 Colour printing press with or without 1 perfector
4 Colour printing press with 2 perfectors
same as version (01), however special sorts of paper
same as version (02), however special sorts of paper
5 Colour printing press with or without 1 perfector
6 Colour printing press with or without 1 perfector
8 Colour printing press with or without 1 perfector
5 Colour printing press with 2 perfectors
6 Colour printing press with 2 perfectors
8 Colour printing press with 2 perfectors
same as version (05), however special sorts of paper
same as version (06), however special sorts of paper
Y
(cardboard)
(cardboard)
(cardboard)
(cardboard)
Noise level
Weight
approx.
average
max.
670 kg
709 kg
709 kg
50 Hz:
50 Hz:
748 kg
74 dB(A)
76 dB(A)
705 kg
60 Hz:
60 Hz:
78 dB(A)
80 dB(A)
744 kg
744 kg
783 kg
LZA 2200 (08)
KTA 80 / 1
KTA 100 / 4
KTA 140 / 1