3.7
Operating mode on standard operation
The actuator runs by connecting the mains voltage from the „Open" position to the
„Closed" position. By switching the mains voltage to the other input, the actuator runs from the „Closed" position to the „Open"
position. The end positions are defined by two limit switches.
3.7.1
Safety position
In case of power failure, the actuator stays in its current position.
3.8
Technical specifications
3.8.1
Specifications
Specifications
Torque
Voltages
Cycle time
Duty Cycle
L/W/H [mm]
L/W/H [inch]
Weight
Flange interface
Protection class
Accessories
Housing material
3.8.2
Dimensions EA04 10Nm
EA04
10 Nm
110 – 240V AC/ DC
24V AC/ DC
20 s/90°
75%
169/104/123
6.67/4.09/4.87
0,9 kg
F03/ 05
IP65
Limit switch mechanical
PA-GF
EA04
20 Nm
85 – 240V AC/ DC
24V AC/ DC
12 s/90°
75%
177/110/149
6.97/4.34/5.87
1,5 kg
F03/ 05
IP65
Limit switch mechanical
PA-GF
Electric Actuators Type EA04