Instruction manual
4.3
Connection diagram
The power supply is connected with the large, grey DIN plug.
The potential-free connection is made via the small, black DIN plug.
OPEN
WARNING!
Water getting in.
Damage and/ or destruction of the actuator. Danger of injury possible.
► Before the plug is attached, ensure that the rubber seal is on the DIN plug.
4.4
Limit switches
The two end positions in the actuator have been factory set to 90°.
NEUTRAL o (-)
PIN 1
PIN 1
PIN 4 IS THE CONNECTION TO EARTH OR GROUND
PIN1
OPEN
CLOSE
CLOSED
EARTH CON-
DUCTOR
Electric Actuators Type EA04
PHASE o (+)
ACTUATING
MOVEMENT
PIN 2
CLOSED
PIN 3
OPEN
PIN2
PIN 3
"CLOSED"-
"OPEN"- POSITI-
POSITION
ON FEEDBACK
FEEDBACK
17