Descargar Imprimir esta página

+GF+ 582 Manual De Instrucciones página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
4
Technical specifications
4.1
Specifications
Attribute
Dimensions
Materials
Diaphragm
Gaskets
Connections
Pressure level (nominal pressure)
Adjustable pressure ranges
Hysteresis
Pressure difference
4.2
Kv 100-values
DN
Zoll
(mm)
(inch)
10
3/8
15
1/2
20
3/4
25
1
32
1 1/4
40
1 1/2
50
2
4.3
Pressure-temperature diagram
d
Kv 100
(mm)
(l/min)
Type 582
16
45
20
48
25
112
32
129
40
254
50
293
63
319
Value
DN 10-50 (3/8" – 2")
PVC-U, PVC-C, PP-H, PVDF
EPDM/PTFE
EPDM, FKM
Fittings, spigots
PN 10
0.5 - 9 bar / optional 0.3 - 3 bar
(7 - 130 psi / optional 4 - 44 psi)
max. 0.5 bar (max. 6 psi)
Pressure difference between inlet and outlet:
min. 1 bar
Kv 100
Type 586
Type 582
50
2700
53
2850
114
6700
125
7730
263
15240
286
17590
293
19170
Type 582/586
Pressure Control Valves Type 582/586
(l/h)
Type 586
Type 582
3020
3.1
3150
3.3
6840
7.8
7500
9.0
15760
17.7
17140
20.4
17610
22.2
T Temperature (°C, °F)
P Permissible pressure (bar, psi)
The pressure-temperature
diagram is based on a service
life of 25 years with water or
similar media.
Cv 100
(gpm)
Type 586
3.5
3.6
7.9
8.6
18.1
19.7
20.2
15

Publicidad

loading

Este manual también es adecuado para: