Pressure Control Valves Type 582/586
WARNING!
Do not adjust the pressure gauge!
Pressure gauge is installed, preset and tested at the factory.
► Make sure that no modifications are made to the pressure gauge.
5.3.1
Type „Radial installation and removal":
Connection variant: radial installation and removal
1.
Loosen the coupling nut and slide it on the intended pipe end.
2.
Connect the connection parts with the pipe ends. For instructions concerning the different connection types, see planning fun-
damentals.
3.
Put pressure reducing valve type 582/pressure retaining valve type 586 between the connection parts.
4.
Tighten the coupling nuts by hand
5.3.2
Spigot ends
Connection variant: spigot ends
Flange version
► If adapted to flange version, observe the tightening torques of the flanges, see „Georg Fischer planning fundamentals".
Cemented connection
► Only join identical materials.
► After the curing time of the joint has elapsed, rinse the pipe section as quickly as possible with pressure-less water, see chapter
„Jointing techniques" in the „Georg Fischer planning fundamentals".
Welded connection
► Only join identical materials, see chapter „Jointing techniques" in the „Georg Fischer planning fundamentals".
18
Operating Instructions