With the appliance running
Press this key once or more to enter the function and set the switching off delay time (from 1
to 24 hours), the led TIMER blinks.
When the value set on the display stops flashing, the value is saved and the led switches steady on.
When the set time finishes, the appliance switches off.
To deactivate the function, set the operation time to "00" or switch off the appliance.
Timer led
The led switches on when the function is active.
While the led flashes, it is possible to set the operation time (from 1 to 24 hours). Once the
desired time has been selected, wait for the led to stop flashing; the function is active.
HUM key
While the appliance is running, press this key to increase or decrease the percentage of desired
humidity in the room.
Default value is 50% - Value settable from 20% to 80% (steps of 5 at a time).
It is not possible to change the percentage of humidity in "DRY" mode.
Keep key "HUM" pressed for about 3 seconds, the display shows the room temperature (°C).
Fan key
Press this key when the appliance is running to select the desired fan speed.
- Maximum speed
- Minimum speed
It is not possible to change the fan speed during defrost function.
Mode key
Press this key when the appliance is running to select the desired function.
- "Dry" mode
- "Auto" mode
"SLEEP" key
Press key "SLEEP" when the appliance is running.
The led "
" switches on and the function is active; intensity of the switched on led decreases
and the fan speed is automatically set to "minimum".
Default level of humidity is 60%.
To exit the function, press key "SLEEP" again.
Children safety lock
When the appliance is active, keep key "LOCK" pressed for about 3 seconds.
The led "
" switches on and the function is active; all the keys don't work.
In order to exit the function, keep key "LOCK" pressed.
Display
The display has three functions.
• When the appliance is running, it shows the percentage of humidity in the room.
• During the percentage of humidity setting ("HUM" key), it shows the percentage of humidity
you desire to set (if no key is pressed within 5 seconds, the display returns to show the
percentage of humidity in the room).
- Led
switched on
- Led
switched on
- Led "
" switched on
- Led "
" switched on
• If room humidity is ≥ by 3% with respect to the set level of humidity,
the fan activates.
After approximately 3 seconds, the compressor also switches on.
• If room humidity is ≤ by 3% with respect to the set level of humidity,
the compressor switches off. Then, after approximately 30 seconds,
the fan stops running.
EN - 18