6. PROBLEMS: CAUSE AND SOLUTION
Below is a table of possible anomalies, their causes and solutions:
PROBLEM
1. Rejects smoke and / or
insufficient draught
2. Excessive dirt on glass
3. Glass bleaching or
colour fading of the plate
4. Poor heating
5. Venting smoke and / or
gases from the front, bad
smell
6. Excessive draft
7. Poor draft
CAUSE
Incorrect duct
Lack of air supply for combustion
Incorrect position of registers
Incorrect duct
Inappropriate fuel
Overly closed registers
Excessive temperature caused by excessive
heat in the combustion chamber
Inappropriate fuel
Insufficient load
Combustion control registers in the wrong
position
First lighting
Flammable or combustible items in the
enclosure
or
surrounding
equipment
Crack in the combustion chamber of the
equipment
Incorrect duct
Combustion control registers in the wrong
position
Incorrect duct
Duct dirtiness
SOLUTION
Duct servicing*:
-connection
-diameter
-leaks
-insufficient length
-outdoor access
-possible elements blocking the exit
Check vents and / or outside air supply.
Simultaneous operation with other ventilation
devices and / or heating
Setting the register
Revise section on insufficient flue (below).
Use recommended fuel
Adjust registers
Check the fuel load avoiding overheating
Adjust registers
Use recommended fuel
Adding fuel
Adjust registers
Wait for the polymerization process of the paint to
finish; this can take from one to several lightings.
Review of insulating materials such as fiberglass,
fireproof wood or any inflammable elements and
walls
of
the
replace them.
Check for tightness and if you discover a crack,
please contact your dealer.
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
Open the primary and secondary register following
the steps outlined in the manual. Should this not
have an effect, check that the flue duct is clean; if it
is not clean, contact a professional to clean this. If
the problem persists contact your dealer.
13