TABLE "B" - LOGICS
DIP
Logic
Transmitter
1
programming
2
BAR / 8K2
Photocell input
3
check
4
Edge input check
Photocells
5
during closing
6
Fast closing
Block pulses
7
during opening
8
3-step logic
Safety edge input
6
operation
7
Fast closing
Residential /
apartment
8
building
operation
22 -
VIVO 424
INSTALLATION MANUAL
INSTALLATION MANUAL
Cross out
Default
setting used
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
Description
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new
transmitters.
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters and automatic addition of clones.
Transmitters are memorized only using the relevant Radio menu or automatically with replays.
IMPORTANT: Disables the automatic addition of new transmitters and clones
Input configured as Bar 8k2. Input for resistive edge 8K2.
The command reverses movement for 2 sec.
Input configured as Bar, safety edge.
The command reverses movement for 2 sec.
Enable safety check on the PHOT input
Safety check on PHOT input not enabled
Enable safety check on the BAR input
Safety check on BAR input not enabled
In the event beam is broken, photocell operation is disabled during opening. During closing,
movement is reversed immediately.
When beam is broken, photocells are active during both opening and clo-
sing. When beam is broken during closing, movement is reversed only once the
photocell is cleared.
Only active on FW < 3.03
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Logic not enabled
The start pulse has no effect during opening.
The start pulse has effect during opening.
Switches to 3-step logic; during closing, start
reverses movement.
Switches to 4-step logic.
Only active on FW ≥ 3.03
Safety edge with active reversal only when closing, when opening the movement stops
Safety edge with active reversal in both directions
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Logic not enabled
Sets the automation type of operation:
ON = Apartment building
OFF = Residential
Reaction to the START input (wired or radio):
Residential
CLOSED
Opens
WHILE CLOSING
Stops
OPEN
Closes
WHILE OPENING
STOPS + TCA
AFTER STOP
Opens
Reaction to the OPEN input (wired):
Residential
CLOSED
Opens
WHILE CLOSING
Opens
OPEN
No effect
WHILE OPENING
Keeps it open
AFTER STOP
Opens
Reaction to the PEDESTRIAN input (radio):
Residential
CLOSED
Opens partially
WHILE CLOSING
Stops
OPEN
Closes
WHILE OPENING
STOPS + TCA
AFTER STOP
Opens partially
CLOSED
DURING CLOSING
OPEN
DURING OPENING
AFTER STOP
Apartment building
Opens
Opens
Closes
No effect
Opens
Apartment building
Opens
Opens
No effect
Keeps it open
Opens
Apartment building
Opens partially
Opens partially
Closes
No effect
Opens partially
3 step
4 step
opens
opens
stop
closes
closes
stop +
stop +
TCA
TCA
opens
opens